The core wire of the communication signal wire IO control cable is made of modified PE material, and the sheath is made of modified PVC material, which improves the wear resistance and anti-interference performance of the product while improving its stability. The conductor adopts tinned soft copper wire, which can reduce the oxidation of the conductor. The core wire is twisted in pairs to prevent signal interference and attenuation between the core wire and the core wire. The shielding layer is made of flexible tinned soft copper wire and aluminum foil layer. Reduce the oxidation of the shielding layer, the shielding rate is over 85%, and the interference during use is reduced! Ensure that the cable signal transmission rate is longer and more stable
The core wire of the communication signal wire IO control cable is made of modified PE material, and the sheath is made of modified PVC material, which improves the wear resistance and anti-interference performance of the product while improving its stability. The conductor adopts tinned soft copper wire, which can reduce the oxidation of the conductor. The core wire is twisted in pairs to prevent signal interference and attenuation between the core wire and the core wire. The shielding layer is made of flexible tinned soft copper wire and aluminum foil layer. Reduce the oxidation of the shielding layer, the shielding rate is over 85%, and the interference during use is reduced! Ensure that the cable signal transmission rate is longer and more stable
Communication Signal Wire IO Control Cable Technical Data
1. HDPE insulation, flexible PVC sheath
Has good bending resistance
2. Meet the requirements of UL20276
3.Temperature range:
Mobile installation -5°C to +80° c
Fixed installation -15°C to +80°c
4. Nominal voltage 30 v
5. Test voltage 500 v
6.Insulation resistance:
Minimum 20 MOhm x km
7.Minimum bending radius:
Mobile installation 7.5×cable diameter
Fixed installation 6×cable diameter
8. Meet the requirements of EU RoHS and Reach regulations
Communication Signal Wire IO Control Cable Structure
Tinned copper conductor, thin copper wire
Meets UL 20276 requirements
HDPE insulation
Color core wire identification
Wire cores are stranded in layers with the best pitch
Improved tinned copper wire braided shield
Minimum coverage 85%
Special PVC outer sheath
Black (RAL 9005) matte
NO. | Product Code | Conductors x Cross-sec | Outter Diameter | Sheath Color | 20℃ Conductor DC resistance | |
NO.X mm² | mm | Ω/km | ||||
1 | IO-YY06.50.0008 | 25X2X0.08 | 9.2 | Black | 239 | |
2 | IO-YY06.40.0008 | 20X2X0.08 | 8.4 | Black | 239 | |
3 | IO-YY02.50.0008 | 50X0.08 | 8.4 | Black | 239 | |
4 | IO-YY02.40.0008 | 40X0.08 | 7.5 | Black | 239 |